Using the past two
decades of experience and best available technology, Neuroscan is
pleased to offer the SynAmps2 to the Neuroscience
community. Dedicated to high-density recordings, SynAmps2
is a 70 Channel amplifier system, consisting of 64 monopolar, 4 bipolar
and 2 high-level channels. Each channel has a dedicated 24 bit A-to-D,
to ensure the most accurate sampling available.
Active Noise Cancellation is an integral feature of the
SynAmps2 design, providing unparalleled noise immunity.
This ensures an accurate representation of the neurophysiological
activity even in the most hostile electromagnetic environments.
Using the latest technology has not only allowed us to make the
SynAmps2 our most capable amplifier ever, it has also
allowed us to put it into a small, cost effective package.
SynAmps2 Consists of Three Components:
Headbox - Each Headbox consists of 70 channels, and multiple
Headboxes can be linked together to build high-density systems. Our
modular approach to amplifiers provides a simple and flexible upgrade
path.
All of the essential electronics have been moved to the Headbox. Our low
noise 24 bit A-to-D chip allows for low gain to be used while still
maintaining the resolution required for the most critical researcher.
Data is digitized immediately in the headbox and transmitted to the host
computer via a high-speed USB-2 connection guaranteeing lossless
transmission. Quality of the signal is assured by our impedance testing
circuitry, which allows you to verify impedance both on the Headbox and
in a software display.
Touch-proof connectors are provided to allow for the greatest
flexibility, while our high-density connector permits Quik-CapTM
to be easily connected. Inputs for high-level signals are also provided,
allowing you to capture the time series data of other measures along
with the EEG.
System Unit - Serving as a hub for multiple Headboxes, the system
unit is the distribution center, assuring absolute synchronization of
sampling and triggers between all of the Headboxes. The System Unit is
also the communication center with the host computer. Using a USB2
connection, the system unit ensures accurate transmission of data and
trigger timing information.
Power Unit - Isolation of the subject from the power mains is a
critical safety aspect of a complete system. The Power Unit houses a
medical grade transformer, allowing you to connect those devices that
contact the subject to one reference point. This assures that leakage
currents and proper grounding meet world wide certification safety
requirements for patient connected devices.
Design
Features
Headbox-Based Amplification - Analog
signals, whether buffered or not, are susceptible to noise. With the
SynAmps2, signals are amplified and digitized right at
the patient side, providing a digital signal transmission path and
providing the very best signal integrity.
70 Channel Headbox
Units - Allows you to use ALL of your channels. The
SynAmps2 offers two external auxiliary and four bipolar
inputs in addition to the standard 64 channels per headbox. You don't
have to convert bipolar channels to monopolar to get your full montage.
Check Electrode Impedances Right at the
Headbox - Electrode impedances are checked against a
user-selectable threshold and the results are instantly available at the
headbox.
Compact System Design - Each
system consists of one or more headboxes, weighing in at less than 5
lbs, a system unit and a power unit. System and power units will handle
multiple headboxes for high-density recordings.
Up to 256 EEG Channels on a Single Small
System Unit - A single system unit will handle up to four head
boxes, creating a 256 channel system in about one quarter the space of
the original SynAmps unit. Combine two system units to create a
super-high density system.
Standard Windows Computer and USB 2.0
Interface - Plug and play operation makes connection and setup
easy and fast. No proprietary analog to digital, PCI or data interface
cards need to be installed, complicating the system. The industry
standard USB 2.0 interface will allow you to move to another PC easily.
Quik-Caps from Neuromedical Supplies
Connect Directly - Conversion (EBA) cables are no longer
required for cap connection. Neuromedical Supplies Quik-Caps connect
directly to the quick-disconnect high-density connector on each headbox
for no-problem patient setup. Touch Proof connections for each channel
are also provided.
Technical Features
24-Bit Data Conversion - Even
within all the excellent high-bit count analog to digital (A/D)
converters currently on the market, we"ve specially selected the
quietest product available for use in the new SynAmps2,
delivering the best signals with the greatest dynamic range possible.
You demand clean, high-resolution data and we deliver it. Data from the
SynAmps2 also flows seamlessly through to the new
32-bit version of Scan.
Active Noise Cancellation -
Provides unparallel noise immunity. This ensures an accurate
representation of the neurophysiological activity even in the most
hostile electromagnetic environments
10G Ohm Input Impedance - The very
best in instrumentation amplifier technology is used to ensure that your
signals are faithfully recorded.
External (auxiliary) Sensors can be
Connected With Ease - Two external inputs per headbox come
standard. Both are isolated from patient and computer connections with
a+/-5 volt input range. Data is time locked with the EEG data.
External (auxiliary) Sensors Require No
External Power - Sensors can be powered from the headbox. up to
+/-10V at 100mA. This enables use of strain gauges and a wide range of
input devices where the output is time locked to the acquired data.
Bandwidth/Acquisition Rates for the Studies
You Want to Run - You want the capability to go from GSR to ABR
in one instrument. If you need extra bandwidth and higher acquisition
rates, SynAmps2 should be your device of choice. With
SynAmps2, you will never wonder if part of the signal
you needed for source or other analysis is above the bandwidth of your
data collection device.
Advanced Impedance Technology -
Enables the use of advanced impedance modeling techniques and allows you
to obtain impedance of the reference electrode in addition to the
typical recording channels.
System Integration Features
Built-In Compatibility With Other Neuroscan Products - The
seamless system integration that you've come to expect from Neuroscan
continues with SynAmps2. A totally integrated system
including amplifier, data acquisition, stimulus generation, data
analysis, and source analysis means that you spend your time doing
research, not putting systems together.
Backwards Compatibility With Your Existing STIM or Other Stimulus
Generation Programs - SynAmps2 uses the same
trigger connector that the original SynAmps and NuAmps use, so there is
no need to modify your existing stimulus protocols.
MagLink Compatibility - SynAmps2 was designed
with the difficulties of recording in the MRI in mind. Specific
engineering considerations were built in to the system to provide the
best possible recordings in the MRI.
Advanced De-blocking Circuitry - Allows for recording of TMS and
other high intensity stimuli, maximizing the data integrity without
affecting the amplifier.
Extended Cabling Systems - Allows your headbox to be positioned
up to 10m away from the system unit for maximum flexibility. Cabling and
filters for shielded room patch panels will also be available.
Head box Mounting Options - Multiple mounting options, including
wall, tripod and table mount, ensure that head box can be secured in
your recording environment.
Integrated Power Supply - In addition to powering the SynAmps2,
the power unit will allow you to power up to 4 additional devices,
ensuring a common ground is used in all of your patient connected
equipment.
- Monopolar Channel
Count......64 Per Headbox, 256 Per System Unit
- Bipolar Channel
Count...........4 Per Headbox, 16 Per System Unit
- High Level
Channel Count.....2 Per Headbox, 8 Per System Unit
- Maximum Sampling
Rate.......20,000 Hz / Channel all channels driven
- Sampling
Method..................All Channels Sampled Simultaneous
- A/D
Resolution.....................24 Bit
- Input
Impedance..................10 GOhms
- CMRR...................................108
dB
- Input
Noise...........................4 uVpp, .01 - 100 Hz
-
Bandwidth...........................DC to 3500 Hz
- Low Pass Filter
(Maximum)..-3 dB at 3500 Hz, single pole
- High Pass Filter
(Minimum)...DC or -3 dB at .05 Hz, single pole
- Full Scale Input
Range (DC Mode).....+/- 200 mV
- System Gain (DC
Mode)......10
- Sensitivity (DC
Mode)..........24 nV/bit
- Full Scale Input
Range (AC Mode).....+/- 995uV
- System Gain (AC
Mode)......2010
- Sensitivity (AC
Mode)..........3 nV/bit
- Digital (TTL)
Inputs...............8 Bit Stimulus, 8 Bit Response
- High Level Input
Range........+/- 5 V
- Impedance
Measurement.....1K Ohm to 50 K Ohm
- IMRR....................................127
dB
- Headbox Size (h x
w x d)...4.5 x18.7 x 21.8cm, per 64 channels
- Headbox
Weight..................1.5 kg
- System Unit
Size.................23 x 11.6 x 32.5 cm per 256 channels
- System Unit
Weight.............4.3 kg
- Power Unit
Size..................23 x 11.6 x 32.5 cm per 256 channels
- Power Unit
Weight..............12.5 kg
- Device
Certification
- EU Risk
Classification 2B
- Type CF
- FDA Class II
- FDA Product Code
GWQ, GWP, GWF, GWE, GWJ
- Safety
Specifications
- EN 60601-1
Medical Electrical Devices - General Requirements for Safety
- UL2601.1 -
Including US National Deviations for IEC601-1
- CSA22.2 -
Including Canadian National Deviations for IEC601-1
- EN 60601-1-1 -
Collateral Standard - Systems
- EN 60601-1-2 -
Collateral Standard - Electromagnetic Compatibility
- EN 60601-1-4 -
Collateral Standard - Programmable Systems
- EN 60601-2-26 -
Specific requirements for electroencephalographs
Offered in or 64
monoplar channel models. Can be chained together for simultaneous
acquisition of 64, 96, 128 or 256 monopolar channels.
SCAN/ESI 4.3 (or
greater)
|